Zinc hybrid cathode long-duration battery storage, 4-12 h, levelised cost of storage

Aqueous zinc battery plant of the Eos Znyth type, 0.1 to 200 MWh and 4 to 12 h: LCOS in EUR/MWh discharged from PNNL-33283 costs and method with Eos efficiencies, battery-module replacements, energy discharged and charged, and an out-of-sourced-domain flag outside 1-10 MW and 4-10 h.

  • CurrencyEUR 2021
  • Battery limitfully financed
  • 71 documented assumptions
  • Updated27 Oct 2026

Mass and energy balance

What the asset draws and delivers for the case and load you choose.

Reference case

capacity factor: 100.0 %

Hours a year the plant is available to cycle. Cycles = service hours / duration of one cycle (charge + discharge + two rests, PNNL Eq. 2), capped at 365 equivalent full cycles a year. At 8,760 h this is the PNNL duty: 456 cycles at 80 % depth up to 10 h.

Flows

  • In: Electricity for charging—

Asset

Zinc hybrid cathode long-duration battery storage

  • Out: Electricity discharged—

Annual quantities at the current usage.

Rated energy of the zinc battery plant. The catalogue binds products here: one Eos Indensity Core is 0.13334 MWh. PNNL costs zinc systems only at 1 and 10 MW; below 1 MW or above 10 MW of rated power the specific CAPEX is held at its 1 MW or 10 MW value and the out-of-sourced-domain flag shows 1.

System power
— MW
Usable energy per cycle
— MWh
Energy discharged
— MWh/a
Equivalent Eos Indensity Cores
— units

CAPEX

Specific cost at this size, what backs it, and how it behaves with scale.

Specific CAPEX at this size

—

Reference size 10 MWh

Derived from PNNL-33283 Table 4.17

Model value: PNNL total installed cost at your duration and size. Customized: your own quote per kWh of nameplate energy, used as is at every size; the value is then no longer sourced.

Specific CAPEX by energy capacity (nameplate)

Log in to view this sensitivity chart.

  1. Ex-factory
  2. Installed
  3. Fully financed· this figure
CAPEX at the battery limit—

Included

  • Equipment and installation
  • Indirect and owner's costs
  • Contingency

Not included

  • Nothing

Added at project level

  • Nothing: project mode uses the figure as is

Lifetime and replacements

Energy per unit rises as the component wears and resets at each replacement.

Multiplies the PNNL cycle life (5,000 cycles at 80 % depth) and calendar life (15 years) of the battery modules. 1 keeps the sourced values.

Not passed to project mode

LCOS: module replacements is left out of project results: project mode only replaces the whole asset at the end of its lifetime. Add it by hand until it does.

Project figures

Values passed to project mode when this asset is added to a project.

Concept sketch, not to scale · drag to rotate

Electricity for charging in
—
Electricity discharged outMain product
—
CAPEX to the battery limit
—
Fixed O&M
—
Variable O&M, excluding feedstocks
0 EUR/year
Asset lifetime
20 years
LCOS: module replacementsNot applied by project
—

Log in to add this asset to a project.

Levelised cost of storage

A standalone indicator for a quick read. Project mode recomputes it for the whole system.

—

  • LCOS: initial capital—
  • LCOS: module replacements—
  • LCOS: fixed O&M—
  • LCOS: charging—

Linked to the balance above

capacity factor: 100.0 %

Hours a year the plant is available to cycle. Cycles = service hours / duration of one cycle (charge + discharge + two rests, PNNL Eq. 2), capped at 365 equivalent full cycles a year. At 8,760 h this is the PNNL duty: 456 cycles at 80 % depth up to 10 h.

Hours of discharge at rated power; rated power = energy / duration. Efficiency rises with duration (Eos: 81 % DC at 4 h to 88 % at 10 h) and the cost per kWh falls slightly. Above 10 h nothing is published: the 10 h values are held and the flag shows 1.

Average price of the electricity bought to charge. Default 25.36 EUR/MWh: PNNL's 0.03 USD/kWh at the ECB 2021 rate. Divided by the AC round-trip efficiency in the LCOS.

Real, pre-tax rate of the capital recovery factor and of the module replacements. Default 6.52 %, PNNL-33283 Table 6.1. Real, because all costs are in constant 2021 money.

Years over which the CAPEX is recovered and battery modules are replaced. 20 years is PNNL; 25 years is the Eos expected life.

Levelised cost of storage by service hours per year

Log in to view this sensitivity chart.

Benchmarks

This model's figures against published references and reference cases.

Levelised cost of storage, EUR/MWh

126.8 PNNL-33283 §6.2.2, converted

169.1 PNNL-33283 §6.2.1, converted

338.2 PNNL-33283 §6.2.1, converted

Specific CAPEX, EUR/kWh

246 PNNL-33283 Table 4.18, converted

376.3 PNNL-33283 Table 4.17, converted

AC round-trip efficiency, %

75 PNNL-33283 Table 4.25

Reference cases at this size and usage

Log in to compare the reference cases.

All results

Every model output at the current settings, grouped, with the sensitivity charts.

71 outputs · 6 groups · 21 also shown above, dimmed

Levelised cost

8
Levelised cost of storage
ComputingEUR/MWh
LCOS: initial capital
ComputingEUR/MWh
LCOS: module replacements
ComputingEUR/MWh
LCOS: fixed O&M
ComputingEUR/MWh
LCOS: charging
ComputingEUR/MWh
Capital share of LCOS
Computing%
LCOS in USD
ComputingUSD/MWh
PNNL charging price
ComputingEUR/MWh

Size and CAPEX

15
System power
ComputingMW
System power in kW
ComputingkW
Equivalent Eos Indensity Cores
Computingunits
Out of sourced domain
Computingflag
Total CAPEX
ComputingEUR
Specific CAPEX
ComputingEUR/kWh
Model specific CAPEX
ComputingEUR/kWh
PNNL 10 MW installed cost
ComputingUSD/kWh
PNNL 10 MW installed cost in EUR
ComputingEUR/kWh
Power used in the size law
ComputingMW
PNNL 1 MW, 4 h installed cost
ComputingEUR/kWh
CAPEX per kW
ComputingEUR/kW
Storage-block cost
ComputingUSD/kWh
Cost of one module replacement
ComputingEUR
Storage-block share of CAPEX
Computing%

Efficiency and energy balance

14
AC round-trip efficiency
Computing%
DC round-trip efficiency
Computing%
Inverter and transformer efficiency
Computing%
AC round-trip efficiency (fraction)
Computingratio
Model AC efficiency at 4 h
Computing%
Gap to PNNL 4 h efficiency
Computing%
Energy discharged
ComputingMWh/a
Energy charged
ComputingMWh/a
Heat and losses
ComputingMWh/a
Charging energy per MWh discharged
ComputingMWh/MWh
Usable energy per cycle
ComputingMWh
Discharge capacity factor
Computing%
Average discharge power
ComputingMW
Lifetime energy discharged
ComputingMWh

Duty cycle

13
Duration used in the tables
Computingh
Depth of discharge
Computingratio
Rest time per half-cycle
Computingh
Discharge time per cycle
Computingh
Charge time per cycle
Computingh
Duration of one cycle
Computingh
Cycle cap at 80 % depth
Computingcycles/year
Cycles the schedule allows
Computingcycles/year
Cycles per year
Computingcycles/year
Equivalent full cycles per year
Computingcycles/year
Discharge hours per year
Computingh/year
Charging hours per year
Computingh/year
Share of service hours spent cycling
Computing%

Module degradation

10
Average usable energy over module life
Computingratio
Capacity-fade penalty
Computing%
Capital cost per MWh, new modules
ComputingEUR/MWh
Capital cost per MWh, worn modules
ComputingEUR/MWh
Module cycle life
Computingcycles
Module calendar life
Computingyears
Battery-module life
Computingyears
Battery-module life in service hours
Computingh
Module replacements over life
Computingcount
Module replacements, undiscounted
ComputingEUR/year

Finance and yearly costs

11
Discount rate (fraction)
Computingratio
Capital recovery factor
Computing1/year
Discount factor per module life
Computingratio
Present-value factor of replacements
Computingratio
Present value of module replacements
ComputingEUR
Present value of capital
ComputingEUR
Annualised initial CAPEX
ComputingEUR/year
Annualised module replacements
ComputingEUR/year
Fixed O&M
ComputingEUR/year
Charging cost
ComputingEUR/year
Total annual cost
ComputingEUR/year

Sensitivities

6 charts
LCOS components vs service hours per year

Log in to view this sensitivity chart.

LCOS components by discharge duration

Log in to view this sensitivity chart.

Specific and total CAPEX vs energy capacity

Log in to view this sensitivity chart.

DC and AC round-trip efficiency vs duration

Log in to view this sensitivity chart.

Cycles and energy discharged vs duration

Log in to view this sensitivity chart.

LCOS vs charging price

Log in to view this sensitivity chart.

About

Calculator context

Grid-connected long-duration battery plant built from aqueous zinc hybrid cathode modules of the Eos Znyth type (Eos Indensity Core, 133.34 kWh per unit), with power conversion and transformer. You set the nameplate energy (0.1 to 200 MWh), the discharge duration (4 to 12 h), the hours a year the plant is available to cycle and the reference case. The method is the PNNL-33283 levelised cost of storage (DOE Energy Storage Grand Challenge, 2022, §6, Eq. 1-3), simplified to a real pre-tax capital recovery factor instead of PNNL's fixed charge rate with US taxes.

Efficiency: the Eos datasheet prints a maximum DC round-trip efficiency of 81 % at 4 h rising to 88 % at 10 h, lower than lithium; four inverter and transformer passes at 98 % each (PNNL §4.4.4.4) bring it to AC. At 4 h this gives 74.7 % AC, against 75 % in PNNL Table 4.25 from an independent source. Duty: cycles follow PNNL Eq. 2 with the zinc rest times of Table 6.3, capped at 365 equivalent full cycles a year at 80 % depth of discharge. Degradation: battery modules reach end of life at 80 % of rated energy with a linear decline (PNNL §6.1.5, §4.4.4.2), so the plant delivers on average 90 % of its new usable energy; modules last the shorter of 5,000 cycles and 15 years and are bought again at the PNNL storage-block cost. CAPEX: PNNL total installed cost of zinc nonflow systems, 375 USD/kWh at 10 MW and 8 h in 2021 (398 to 370 from 4 to 10 h), converted at the ECB 2021 average of 1.18274 USD/EUR, with a size law between 1 and 10 MW derived from PNNL's 445 USD/kWh at 1 MW. The fixed O&M is PNNL's 0.5 USD/kW-year; PNNL's power-equipment overhaul is not modelled.

At 80 MWh, 8 h (10 MW), 8,760 service hours, 6.52 % real and 20 years, the plant costs 317 EUR/kWh (25.4 MEUR), runs 456 cycles a year, discharges 26,280 MWh a year at 79.3 % AC efficiency and gives an LCOS of about 140 EUR/MWh, of which about 20 EUR/MWh is the one module replacement in year 11. PNNL prints 0.20-0.40 USD/kWh for all batteries of 1-10 MW up to 10 h in 2021, i.e. 169-338 EUR/MWh in 2021 EUR: the result sits below that band because the pre-tax CRF leaves out taxes, depreciation and the construction period. The PNNL report text mentions 500 cycles for zinc-bromine nonflow on p.56 while its Table 4.26 prints 5,000; the table is used.

Sourced domain: PNNL costs zinc only at 1 and 10 MW and 4 to 10 h. A single Indensity Core (25 kW), any plant above 10 MW and any duration above 10 h are extrapolations: the calculator holds the nearest sourced value and shows the out-of-sourced-domain flag. No revenue, tax or subsidy: those belong to project mode.

Model

136 variables — inputs, calculations and outputs, with their dependencies.

136 variables shown of 136
VariableValueUnitDepends on
80MWh—
8h—
8760h/year—
1——
0——
317EUR/kWh—
1ratio—
25.36EUR/MWh—
6.52%—
20years—
VariableFormulaUnitDepends on
if((<=)+(<)+(>)+(<=)+(>)+(<)+(>)+(<)+(>)+(<=)+(<=)+(<)+(<)+(>)+(<)>,,)bool
VariableFormulaUnitDepends on
/max(,)MW
*kW
*ratio
*MWh
*/units
clamp(,,)h
if((<)+(>)+(>)>,,)flag
if(<=,+(-)*(-)/(-),if(<=,+(-)*(-)/(-),+(-)*(-)/(-)))%
^*%
**%
*ratio
**%
-%
if(<=,+(-)*(-)/(-),if(<=,+(-)*(-)/(-),+(-)*(-)/(-)))h
*h
/max(,)h
++*h
/max(,)cycles/year
/max(,)cycles/year
min(,)cycles/year
*cycles/year
*h/year
*h/year
*/max(,)*%
(+)*ratio
(-)*%
**MWh/a
/max(,)MWh/a
-MWh/a
/max(,)MWh/MWh
/max(*,)*%
/MW
*MWh
*cycles
*years
min(/max(,),)years
*h
max(ceil(/max(,))-,)count
if(==,if(<=,+(-)*(-)/(-),if(<=,+(-)*(-)/(-),+(-)*(-)/(-))),if(<=,+(-)*(-)/(-),if(<=,+(-)*(-)/(-),+(-)*(-)/(-))))USD/kWh
/EUR/kWh
clamp(,,)MW
clamp(*(/)^(-),,)EUR/kWh
if(>=,,)EUR/kWh
/EUR/kWh
**EUR
/max(,)EUR/kW
if(==,,)USD/kWh
/**EUR
/max(,)*%
*ratio
if(<,/,(*(+)^)/max((+)^-,))1/year
/(+)^ratio
if(<,,*(-^)/max(-,))ratio
*EUR
+EUR
*EUR/year
*EUR/year
*/EUR/year
/*EUR/year
*EUR/year
+++EUR/year
/max(,)EUR/MWh
/max(,)EUR/MWh
/max(,)EUR/MWh
/max(,)EUR/MWh
+++EUR/MWh
*USD/MWh
(+)/max(,)*%
(+)/max(*,)EUR/MWh
(+)/max(**,)EUR/MWh
*/EUR/MWh

Assumptions

71 assumptions used in the calculations

  • Lower limit in the input guards and in the replacement count.

    Market range Exact by definition.

    0
    Numerical constant
  • Unit multiplier in the CRF, the guards, the fade average and the Customized switch.

    Market range Exact by definition.

    1
    Numerical constant
  • Protects divisions against a zero denominator.

    Market range Exact by definition.

    0
    Numerical constant
  • Converts a percent to a fraction.

    Market range Exact by definition.

    0.01
    Numerical constant
  • Converts a fraction to a percent; also the 100 % upper limit of the discount-rate guard.

    Market range Exact by definition.

    100
    Numerical constant
  • kWh per MWh, to apply per-kWh costs to the MWh energy capacity.

    Market range Exact by definition.

    1000
    Numerical constant
  • kW per MW, to apply the per-kW fixed O&M.

    Market range Exact by definition.

    1000
    Numerical constant
  • Hours in a non-leap year: upper limit of the service-hours lever and basis of the capacity factor and average power.

    Market range Exact by definition.

    8760h/year
    Numerical constant
  • Halves the sum of beginning-of-life (1) and end-of-life (0.8) energy to get the average usable energy over one battery-module life.

    Market range No independent range cited.

    0.5
    Derived (linear fade, PNNL-33283 §4.4.4.2)
  • Code of the 2021 reference case in the 'Reference case' select.

    1
    Model selector
  • Code of the 2030 projection case in the 'Reference case' select.

    2
    Model selector
  • Shortest tabulated duration: lower limit of the duration slider and first interpolation knot.

    4h
    PNNL-33283 tables
  • Second interpolation knot.

    6h
    PNNL-33283 tables
  • Third interpolation knot.

    8h
    PNNL-33283 tables
  • Longest tabulated duration. Above 10 h every duration-dependent value is held at its 10 h figure and the out-of-sourced-domain flag is raised: no trend is extrapolated.

    10h
    PNNL-33283 tables
  • Upper limit of the duration slider. 10 to 12 h is an extrapolation zone, flagged on the page.

    12h
    Scope choice
  • DC round-trip efficiency of the zinc hybrid cathode battery at 4 h. A maximum printed by the maker, in 20-80-20 % state-of-charge cycles: a best case, not a warranted average.

    Market range PNNL-33283 Table 4.25 gives 75 % AC-AC for the 4 h nonflow composite, consistent with 81 % DC after the inverter and transformer chain.

    81%
    Eos datasheet
  • DC round-trip efficiency of the zinc hybrid cathode battery at 6 h. A maximum printed by the maker, in 20-80-20 % state-of-charge cycles: a best case, not a warranted average.

    Market range PNNL-33283 Table 4.25 gives 75 % AC-AC for the 4 h nonflow composite, consistent with 81 % DC after the inverter and transformer chain.

    85%
    Eos datasheet
  • DC round-trip efficiency of the zinc hybrid cathode battery at 8 h. A maximum printed by the maker, in 20-80-20 % state-of-charge cycles: a best case, not a warranted average.

    Market range PNNL-33283 Table 4.25 gives 75 % AC-AC for the 4 h nonflow composite, consistent with 81 % DC after the inverter and transformer chain.

    86%
    Eos datasheet
  • DC round-trip efficiency of the zinc hybrid cathode battery at 10 h. A maximum printed by the maker, in 20-80-20 % state-of-charge cycles: a best case, not a warranted average.

    Market range PNNL-33283 Table 4.25 gives 75 % AC-AC for the 4 h nonflow composite, consistent with 81 % DC after the inverter and transformer chain.

    88%
    Eos datasheet
  • One-way efficiency of the inverter and, separately, of the transformer.

    Market range No independent range cited.

    0.98ratio
    PNNL-33283 §4.4.4.4
  • Number of one-way conversion passes in a round trip (inverter and transformer, in and out).

    4
    PNNL-33283 §4.4.4.4
  • Independent check of the efficiency chain: PNNL's composite AC-AC efficiency comes from Richey 2021, not from the Eos 2026 datasheet used by the model.

    75%
    PNNL-33283 Table 4.25
  • Rest after each charge and each discharge at 4 h, in the PNNL cycle-count formula (Eq. 2).

    1.21h
    PNNL-33283 Table 6.3
  • Rest after each charge and each discharge at 6 h, in the PNNL cycle-count formula (Eq. 2).

    0.7h
    PNNL-33283 Table 6.3
  • Rest after each charge and each discharge at 8 h, in the PNNL cycle-count formula (Eq. 2).

    0.59h
    PNNL-33283 Table 6.3
  • Rest after each charge and each discharge at 10 h, in the PNNL cycle-count formula (Eq. 2).

    0.49h
    PNNL-33283 Table 6.3
  • Two rests per cycle, one after charge and one after discharge.

    2
    PNNL-33283 Eq. 2
  • Share of nameplate energy used in each cycle. Fixed, because the cycle life is only sourced at this depth.

    Market range No independent range cited.

    80%
    PNNL-33283 §6.1.3
  • Cap on cycling: 365 equivalent full cycles a year, i.e. 456.25 cycles at 80 % DOD.

    365cycles/year
    PNNL-33283 Eq. 2
  • Usable energy at the end of a battery-module life, as a share of the beginning-of-life energy. With the linear decline it gives an average of 90 %.

    Market range No independent range cited.

    0.8ratio
    PNNL-33283 §6.1.5
  • Cycles before the battery modules reach end of life. Medium evidence: the PNNL text on p.56 mentions 500 cycles for zinc-bromine nonflow while Table 4.26 prints 5,000; the table is kept, and the contradiction is stated here.

    Market range PNNL p.56 text: 500 cycles (inconsistent with Table 4.26).

    5000cycles
    PNNL-33283 Table 4.26
  • Calendar life of the battery modules: the module life is the shorter of cycle life / cycles a year and this value.

    Market range Eos Indensity Core datasheet: expected life 25 years (system, maker claim).

    15years
    PNNL-33283 Table 4.27
  • All-in total installed cost of a 10 MW zinc nonflow system at 4 h, 2021 USD: battery modules, balance of system, power conversion, controls, system integration, EPC, project development and grid integration.

    Market range PNNL-33283 Table 4.17-4.18 nonflow range 291-445 $/kWh across sizes, durations and years.

    398USD/kWh
    PNNL-33283 Table 4.17
  • All-in total installed cost of a 10 MW zinc nonflow system at 6 h, 2021 USD: battery modules, balance of system, power conversion, controls, system integration, EPC, project development and grid integration.

    Market range PNNL-33283 Table 4.17-4.18 nonflow range 291-445 $/kWh across sizes, durations and years.

    383USD/kWh
    PNNL-33283 Table 4.17
  • All-in total installed cost of a 10 MW zinc nonflow system at 8 h, 2021 USD: battery modules, balance of system, power conversion, controls, system integration, EPC, project development and grid integration.

    Market range PNNL-33283 Table 4.17-4.18 nonflow range 291-445 $/kWh across sizes, durations and years.

    375USD/kWh
    PNNL-33283 Table 4.17
  • All-in total installed cost of a 10 MW zinc nonflow system at 10 h, 2021 USD: battery modules, balance of system, power conversion, controls, system integration, EPC, project development and grid integration.

    Market range PNNL-33283 Table 4.17-4.18 nonflow range 291-445 $/kWh across sizes, durations and years.

    370USD/kWh
    PNNL-33283 Table 4.17
  • Small-system anchor of the size law (1 MW against 10 MW at the same 4 h duration).

    445USD/kWh
    PNNL-33283 Table 4.17
  • Projected 2030 all-in installed cost of a 10 MW zinc nonflow system at 4 h, expressed by PNNL in 2021 USD. A projection, hence medium evidence.

    302USD/kWh
    PNNL-33283 Table 4.18
  • Projected 2030 all-in installed cost of a 10 MW zinc nonflow system at 6 h, expressed by PNNL in 2021 USD. A projection, hence medium evidence.

    297USD/kWh
    PNNL-33283 Table 4.18
  • Projected 2030 all-in installed cost of a 10 MW zinc nonflow system at 8 h, expressed by PNNL in 2021 USD. A projection, hence medium evidence.

    292USD/kWh
    PNNL-33283 Table 4.18
  • Projected 2030 all-in installed cost of a 10 MW zinc nonflow system at 10 h, expressed by PNNL in 2021 USD. A projection, hence medium evidence.

    291USD/kWh
    PNNL-33283 Table 4.18
  • Cost of the DC storage block (battery modules) paid again at each module replacement, 2021 case.

    175USD/kWh
    PNNL-33283 Table 4.13
  • Storage-block cost at each replacement, 2030 projection case.

    140USD/kWh
    PNNL-33283 Table 4.14
  • Fixed O&M per kW of rated power. Very low for this chemistry. PNNL's power-equipment overhaul (30 % every 10 years) is not modelled: an estimated few USD/kW-year, stated as a simplification.

    Market range No independent range cited.

    0.5USD/kW/year
    PNNL-33283 Table 4.22
  • Reference charging price, shown converted to EUR next to the charging-price input.

    0.03USD/kWh
    PNNL-33283 Table 6.1
  • Converts the 2021 USD of PNNL to 2021 EUR at the rate of the cost year: currency and year stay matched.

    1.18274USD/EUR
    ECB
  • Lower end of the sourced power range. Below 1 MW the size law is not extended and the flag is raised.

    1MW
    PNNL ESGC zinc
  • Upper end of the sourced power range. Above 10 MW the 10 MW cost is held and the flag is raised.

    10MW
    PNNL ESGC zinc
  • Reference size of the cost anchor.

    10MW
    PNNL-33283 Table 4.17
  • Economy-of-scale exponent on total CAPEX with rated power, applied only between the two PNNL sizes (1 to 10 MW). Two points of one source, hence medium evidence. Outside 1-10 MW the specific CAPEX is held at its end value rather than extrapolated.

    Market range No independent range cited.

    0.9515
    Derived from PNNL-33283 Table 4.17
  • Lower guard of the scaled specific CAPEX; never binds inside the slider domain (checked at every corner).

    100EUR/kWh
    Model guard
  • Upper guard of the scaled specific CAPEX; never binds inside the slider domain (checked at every corner).

    1000EUR/kWh
    Model guard
  • Energy of one catalogue product unit, to express the plant size as an equivalent number of Eos Indensity Cores.

    133.34kWh
    Eos datasheet
  • Low end of the PNNL 2021 battery LCOS band, in 2021 EUR. PNNL uses a fixed charge rate with US taxes and MACRS; this calculator uses a pre-tax real CRF, which lands lower.

    169.1EUR/MWh
    PNNL-33283 §6.2.1, converted
  • High end of the PNNL 2021 battery LCOS band, in 2021 EUR.

    338.2EUR/MWh
    PNNL-33283 §6.2.1, converted
  • Low end of the PNNL 2030 battery LCOS band, in 2021 EUR.

    126.8EUR/MWh
    PNNL-33283 §6.2.2, converted
  • Lowest PNNL zinc nonflow total installed cost, same all-in boundary as the model.

    246EUR/kWh
    PNNL-33283 Table 4.18, converted
  • Highest PNNL zinc nonflow total installed cost, same all-in boundary as the model.

    376.3EUR/kWh
    PNNL-33283 Table 4.17, converted
  • Power of one Indensity Core at 4 h: a single unit is a 0.025 MW system, below the 1 MW PNNL range, so it is costed with the 1 MW figure and flagged.

    25kW
    Eos datasheet
  • Maker's expected system life; the reason the economic-life slider goes to 25 years. The model keeps PNNL's 15-year calendar life for the battery modules.

    25years
    Eos datasheet
  • Default real discount rate of the CRF. Real, because every cost is in constant 2021 money with no escalation.

    6.52%
    PNNL-33283 Table 6.1
  • Default horizon of the CRF and of the module-replacement schedule; also the asset life exported to project mode.

    20years
    PNNL-33283 §6.1.1
  • Method: PNNL-33283 §6 Eq. 1-3, simplified. LCOS = (CRF x (CAPEX + present value of battery-module replacements) + fixed O&M) / energy discharged + charging price / AC round-trip efficiency. Cycles from PNNL Eq. 2 with the zinc rest times; energy discharged from Eq. 3 with the average usable energy of a linearly fading module. CRF real and pre-tax, not PNNL's fixed charge rate with US taxes and MACRS.

    —
    Unspecified
  • Chemistry: zinc-bromine nonflow, i.e. the Eos Znyth zinc hybrid cathode in PNNL-33283 (source Richey 2021 in the report). Aqueous, non-flammable electrolyte with no circulating electrolyte (PNNL §4.4.1.4); no thermal runaway is modelled or costed. Zinc-air is not covered by these numbers.

    —
    Unspecified
  • Real terms: all costs in constant 2021 EUR (PNNL 2021 USD at the ECB 2021 rate), no escalation, annualised at a real rate. The fixed O&M exported to project mode is an undiscounted yearly cash cost that does not depend on the discount rate.

    —
    Unspecified
  • Sourced domain: PNNL zinc costs exist only at 1 and 10 MW and 4-10 h. Outside it (a single Indensity Core of 25 kW, any plant above 10 MW, any duration above 10 h) no trend is extrapolated: the specific CAPEX stays at its 1 MW or 10 MW value, efficiency and rest time stay at their 10 h value, and the out-of-sourced-domain flag shows 1.

    —
    Unspecified
  • Battery-module replacements: the DC storage block is bought again at each multiple of its life that falls strictly inside the economic life, at the PNNL storage-block cost, discounted at the real rate. They are capital, kept out of the O&M exported to project mode; project mode only replaces the whole asset, so the page shows this share separately (BUG-128).

    —
    Unspecified
  • Customized CAPEX replaces the model value at every size, with no size law. The battery-module replacement cost stays at the PNNL storage-block figure of the selected case.

    —
    Unspecified
  • Convergence: PNNL prints a 2021 LCOS of about 0.20-0.40 USD/kWh for all batteries 1-10 MW up to 10 h, i.e. 169-338 EUR/MWh in 2021 EUR. The model nominal (80 MWh, 8 h) sits below that band because the pre-tax real CRF leaves out PNNL's taxes, MACRS and construction period. The gap is stated, not hidden. The efficiency chain is checked against PNNL Table 4.25 (75 % AC-AC at 4 h), an independent source.

    —
    Unspecified
  • Standalone asset sheet: no revenue, tax, subsidy or degradation of efficiency is modelled; those, and the price spread the plant earns, belong to project mode.

    —
    Unspecified